Skip to Content
TotFlex
Metal Expansion Joints · EJMA

Vibration Absorber Expansion Joints

Stainless-steel bellows on loose flanges that decouple a pump, compressor or engine from the connected pipework — absorbing the vibration and structure-borne noise that rigid connections transmit into the line and supports.

DN 25 – DN 1200Size rangePN6 – PN64Pressure-90 to +550 °CTemperature
Vibration Absorber Expansion Joints
/01

Technical Data

Bellow MaterialStainless Steel AISI 304 (opt. AISI 316, AISI 321)
Flange MaterialCarbon Steel St37.2 (opt. AISI 304, AISI 316)
Tie Rod MaterialCarbon Steel St37.2 (opt. AISI 304, AISI 316)
Nut MaterialCarbon Steel (opt. Stainless Steel)
Connection TypesLoose Flange
Connection DiametersDN25 (1″) to DN1200 (48″)
Operating Temperature-90 °C to +550 °C
Operating PressurePN6 / PN10 / PN16 / PN40 / PN64
DesignEJMA Standards
EJMA DESIGNEN 1092-1 / ASME B16.5EN 10204 3.1
/02

Selection Guide

STDStandard — loose flange

Stainless bellows with rotatable flanges for pump and chiller hook-ups.

Best forPumps · chillers
SSAll-stainless

Stainless flanges and hardware for corrosive plant.

Best forCorrosive environments
SETEquipment sets

Matched pairs sized for suction and discharge nozzles.

Best forComplete pump sets
Designed to EJMA — every joint is pressure-tested before dispatch, EN 10204 3.1 certificates on request.
/03

Datasheet & Drawings

Vibration absorber dimensions and materials on one page, plus the technical drawing. A certified approval drawing follows with your quotation.

EN 10204 3.1 material certificates are supplied with your shipment.

Technical drawingProduct datasheet
/05

Frequently Asked Questions

What does a vibration absorber expansion joint do?

It sits between a machine and its piping to isolate vibration and noise, and to take up minor misalignment and thermal movement — protecting connected valves, instruments and joints from fatigue.

Is a vibration absorber the same as a braided metal hose?

No. A vibration absorber is a formed-bellows unit with a fixed length, engineered to damp vibration and small movement, whereas a braided hose is designed mainly for flexible routing and larger deflection. TOTFLEX supplies both, chosen to the duty.

Why are tie or limit rods fitted?

Pump and compressor connections create pressure thrust that would try to stretch the bellows. Tie or limit rods restrain that thrust, hold the joint at its set length and prevent over-extension, while still allowing vibration-damping movement.

Where is it installed on a pump?

Typically at the suction and/or discharge flange, as close to the pump as practical, so vibration is intercepted before it enters the line.

What movements does it absorb?

Small multi-directional movement — modest axial, lateral and angular — combined with high-frequency vibration damping. It is not intended for the large thermal movements that axial or loop-type joints handle.

What materials and sizes are available?

Stainless-steel bellows (304 / 316L) with carbon or stainless flanges, from DN25 upward, each unit sized to the pump duty and connection standard.

Engineered to order. Delivered worldwide.

Send your duty conditions — size, pressure, temperature, medium and connections — and our engineers return a drawing, material selection and lead time.

Request a quote