Sprinklers engineered to protect a wider area per head than standard spray types — pendent and sidewall configurations for light-hazard spaces, cutting the number of heads and drops a project needs.

K5.6 / K8.0K factor26 – 36 GPMDesign curves57 – 79 °CRatings
Extended Coverage Sprinklers
/01

Technical Data

Product codesSP13 – SP20
TypeExtended coverage glass-bulb sprinkler
ConfigurationsPendent · Sidewall
ResponseStandard (5 mm bulb) or Quick (3 mm bulb)
K factorK5.6 (80) · K8.0 (115)
Thread½" NPT (15 mm) · ¾" NPT (20 mm)
Design flows26 / 29 / 32 / 36 GPM (98 – 136 LPM) coverage curves
Temperature ratings57 · 68 · 79 °C
FinishesBrass · Chrome · White
WIDER SPACINGGLASS BULBLIGHT HAZARD
ApplicationsHotelsHospitalsOfficesDormitoriesTrade centersOpen-plan areas
/02

Selection Guide

SP13 – SP16Pendent

Extended coverage below the ceiling. SP13/14 standard response, SP15/16 quick response.

Best forOpen-plan ceilings
SP17 – SP20Sidewall

Wall-mounted wide-throw coverage down the room. SP17/18 standard, SP19/20 quick.

Best forCorridors · long rooms
K5.6 · K8.0Orifice options

Both K factors available in every configuration — matched to the design density and available pressure.

Best forHydraulic flexibility
Extended coverage sprinklers are applied in light-hazard areas per the governing design standard — confirm spacing with the authority having jurisdiction.
/03

Datasheet & Drawings

Each configuration has its own one-page datasheet with the spray coverage curves — download the variant you are specifying.

Test records and material certificates are supplied with your shipment.

Product datasheet
/05

Frequently Asked Questions

What does extended coverage mean?

The head is listed to protect a larger floor area than a standard spray sprinkler of the same K factor, using a deflector designed for a wider throw at the documented flow and pressure points.

Where can extended coverage sprinklers be used?

In light-hazard occupancies — offices, hotels, hospitals and similar spaces — where the design standard permits extended spacing. The layout must follow the coverage curves in the datasheet.

How do the design flows work?

Each variant publishes spray envelopes at 26, 29, 32 and 36 GPM (98 – 136 LPM). The designer picks the curve matching the required density and checks the available pressure at the head.

Should I specify standard or quick response?

Quick response (3 mm bulb) is the usual choice in the light-hazard occupancies where extended coverage applies, but standard response (5 mm) versions are available where the design calls for them.

Which sizes and finishes are offered?

Half-inch and three-quarter-inch NPT threads with K5.6 or K8.0 orifices, in brass, chrome or white finishes at 57, 68 or 79 °C temperature ratings.

Engineered to order. Delivered worldwide.