TLG Valve Magnetic Level Indicator

A magnetic level indicator with integral isolation valves — the bypass chamber can be shut off and drained for inspection or float maintenance without taking the vessel out of service, in stainless-steel construction with no power required.

Isolation valvesIntegralMax 150 °CTemperaturePN10Pressure
TLG Valve Magnetic Level Indicator
/01

Technical Data

Float material304 SS (standard), opt. 316 SS
Body material304 SS (standard), opt. 316 SS
IndicatorBi-colour flap column (bypass principle)
ValvesIntegral isolation & drain
Flap materialPlastic, high-temperature resistant
Process connectionFlanged & threaded (G ½"–1", DN15–DN25)
Flange standardsDIN / ANSI / JIS
Flange materialCarbon steel St 37.2 / stainless (optional)
Other connectionsGland, nipple or sleeve
DIN / ANSI / JIS FLANGESNO POWER REQUIREDEN 10204 3.1
ApplicationsPetrol refineriesOil & gasPharmaceuticalChemicalTextile & paperShipyardsBoilers & tanksPipeline compressor stationsEnergy & power plants
/02

Selection Guide

TLG-VStandard configuration

Bypass chamber with integral isolation and drain valves for in-service maintenance.

Best forContinuous-process plants
TLG-V-TXWith transmitter

Adds a 4–20 mA or 0–10 V level transmitter strapped to the bypass chamber for remote monitoring.

Best forRemote / SCADA monitoring
TLG-V-SWWith magnetic contacts

Magnetic switch contacts clamp anywhere on the chamber for pump control and alarms.

Best forAlarms · pump interlocks
Every indicator is pressure-tested before dispatch — EN 10204 3.1 material certificates on request.
/03

Datasheet & Drawings

The full specification on one page, plus the technical drawing. A certified approval drawing for your exact configuration follows with the quotation.

EN 10204 3.1 material certificates are supplied with your shipment.

Technical drawingProduct datasheet
/05

Frequently Asked Questions

Why choose the valve version?

Its integral isolation and drain valves let you take the indicator out of service, clean or repair it and put it back — without stopping or draining the vessel.

What valves are fitted?

Isolation valves at the process connections plus a drain valve at the chamber base; materials matched to the body specification.

What are the ratings?

PN10 and up to about 150 °C as standard; other ratings on request as engineered builds.

Does maintenance require special tools?

No — close the isolation valves, drain the chamber and unbolt it like any flanged spool.

Can it carry a transmitter and contacts?

Yes — external transmitters and magnetic switch contacts fit exactly as on the standard TLG.

Which materials are available?

304 stainless standard, 316 stainless optional; valve trim to suit the medium.

Engineered to order. Delivered worldwide.