304 / 316 SSBodyMax 180 °CTemperature16 bar · opt 25Pressure
TLG Standard Magnetic Level Indicator
/01

Technical Data

Float material304 SS (standard), opt. 316 SS
Body material304 SS (standard), opt. 316 SS
IndicatorBi-colour flap column (bypass principle)
Flap materialPlastic, high-temperature resistant
Process connectionFlanged & threaded (DN20, PN16)
Flange standardsDIN / ANSI / JIS
Flange materialCarbon steel St 37.2 / stainless (optional)
Other connectionsGland, nipple or sleeve
Drain plug3/8"
DIN / ANSI / JIS FLANGESNO POWER REQUIREDEN 10204 3.1
ApplicationsPetrol refineriesOil & gasPharmaceuticalChemicalTextile & paperShipyardsBoilers & tanksPipeline compressor stationsEnergy & power plants
/02

Selection Guide

TLGStandard configuration

304 SS bypass chamber with bi-colour flap column, flanged or threaded connections.

Best forTanks · process vessels
TLG-TXWith transmitter

Adds a 4–20 mA or 0–10 V level transmitter strapped to the bypass chamber for remote monitoring.

Best forRemote / SCADA monitoring
TLG-SWWith magnetic contacts

Magnetic switch contacts clamp anywhere on the chamber for pump control and alarms.

Best forAlarms · pump interlocks
Every indicator is pressure-tested before dispatch — EN 10204 3.1 material certificates on request.
/03

Datasheet & Drawings

The full specification on one page, plus the technical drawing. A certified approval drawing for your exact configuration follows with the quotation.

EN 10204 3.1 material certificates are supplied with your shipment.

Technical drawingProduct datasheet
/05

Frequently Asked Questions

What makes the TLG Standard the "standard" model?

It is the base configuration — chamber, magnetic float and bi-colour flag rail — with no scale, valves or added instrumentation. It covers the majority of everyday tank and vessel level duties.

How is the level shown?

A column of two-colour flags on the outside of the chamber flips as the float passes, so the boundary between the colours marks the liquid surface continuously and can be read at a glance.

Does it need electrical power?

No. The flag display is driven only by the float's magnet. Power is required solely if you later add level switches or a 4–20 mA transmitter.

Can I add a transmitter or switches later?

Yes. The chamber can be specified ready for reed-chain switches and a transmitter, so you can start with visual indication and add signals when needed.

What is the maximum length available?

Level spans from a few hundred millimetres to several metres are typical; longer spans are engineered as required for tall vessels.

Does TOTFLEX export the TLG Standard worldwide?

Yes — TOTFLEX manufactures it in Turkey and delivers it globally with full documentation.

Engineered to order. Delivered worldwide.

Send your duty conditions — size, pressure, temperature, medium and connections — and our engineers return a drawing, material selection and lead time.